#Hvactools Reel by @hvacknowitall1 (verified account) - Why digital is winning...

The fact that start ups and field repairs can be documented in such a way makes digital tools and apps a clear winner. 

Cu
6.0K
HV
@hvacknowitall1
Why digital is winning... The fact that start ups and field repairs can be documented in such a way makes digital tools and apps a clear winner. Customer complains that you didn't do it right? Well here's your report on start up day sir, but I see you haven't scheduled any maintenance in the last 2 years hmmm. We're at AHR at the @testonorthamerica booth checking out their probes and Testo smart app. #hvac #hvacr #hvacservice #hvacinsallation #hvactroublshooting
#Hvactools Reel by @topgunhvacr - A quick Delta T check during this PM told me something was wrong before I even hooked up gauges.

Too many techs skip this step and go straight to pre
4.9K
TO
@topgunhvacr
A quick Delta T check during this PM told me something was wrong before I even hooked up gauges. Too many techs skip this step and go straight to pressures. Your supply vs return temps can tell you a lot about what’s going on in the system before you even connect gauges. On these Trane Voyagers, you should typically see around 20-25° Delta T with both compressors running. Always verify with: • Saturation temps • Superhest pply vs Return • Subcooling Do you check Delta T before hooking Up gauges? #hvac #hvactech #hvaclife #commercialhvac #hvacarmy
#Hvactools Reel by @hvacknowitall1 (verified account) - How to check decay with a single hose...

When the micron gauge is close to the pump, (which is okay if you perform a decay to test) it can read lower
28.7K
HV
@hvacknowitall1
How to check decay with a single hose... When the micron gauge is close to the pump, (which is okay if you perform a decay to test) it can read lower than the actual system pressure. That's why we must perform a decay test by isolating the system from the pump. We used the @navac_inc NRV1 core tool in this video to perform this test (NRV2 also available). We used the NMV1 micron gauge and NP12DM vacuum pump as well. @supco_hvac Umbrella keeping us shady #hvac #hvaceducation #hvacknowledge #refrigeration #hvacinstallation
#Hvactools Reel by @thehvacgame - Sometimes evacuation problems aren't actually system problems.

Micron gauges live a rough life in the field.

Oil vapor, debris, and contamination ca
3.4K
TH
@thehvacgame
Sometimes evacuation problems aren’t actually system problems. Micron gauges live a rough life in the field. Oil vapor, debris, and contamination can slowly affect the sensor and cause readings to drift or jump around during evacuation. If your micron gauge readings suddenly start jumping around, it definitely could mean non-condensibles boiling off in the system BUT it could als mean the sensor got contaminated. JB’s approach to resolving the doubt you might have is simple but effective. A field replaceable sensor tip. If you’re ever in doubt this could save hours of needless troubleshooting, leak searches, nitrogen purges or waiting for readings to drop when you’re already below 500 micron. Would you use this? PS: Trust your tools. More likely than not if your readings are off there is something wrong. But, I did experience inaccurate readings after sensors got contaminated and it caused a lot of headaches back then. So I wanted to share this as an alternative. Happy HVACing 🤙 #hvac #hvacservicetech #hvacapprentice #hvaclife
#Hvactools Reel by @adamdeckardbaby - When the shaft turns, the windings are cutting through a magnetic field and the motor acts like a generator. That produces a back EMF (voltage) in the
46.6K
AD
@adamdeckardbaby
When the shaft turns, the windings are cutting through a magnetic field and the motor acts like a generator. That produces a back EMF (voltage) in the windings. That ties directly to Faraday’s Law of Electromagnetic Induction. Your ohmmeter is trying to push a small DC current through the winding to measure resistance. But now there’s an induced voltage fighting it. Bottom line: if you try to measure a motors windings to preclude the motor as part of a larger problem, make sure its not spinning, or you may become a parts changer without knowing it! #hvac #hvaclife #hvactech
#Hvactools Reel by @hvac.roja (verified account) - Once your capacitor starts bulging, even a little. ITS BAD! Even if it works while you're there, it is soon to fail!

I didn't showing the video but t
17.8K
HV
@hvac.roja
Once your capacitor starts bulging, even a little. ITS BAD! Even if it works while you’re there, it is soon to fail! I didn’t showing the video but the capacitor that was slightly bulging was also reading 0MFDs. #hvac #hvactraining #hvactips #hvacapprentice #apprentice
#Hvactools Reel by @povhvac - Don't hesitate to start, you'll only wish you did sooner! 

#hvacr #apprenticeships #hvaclife #refrigeration
1.8K
PO
@povhvac
Don’t hesitate to start, you’ll only wish you did sooner! #hvacr #apprenticeships #hvaclife #refrigeration
#Hvactools Reel by @cooperkimblehvac - Rectorseal ECM surge protector addition
.
.
.
#hvac #hvactools #hvacservice #skilledtrades #bluecollar
280
CO
@cooperkimblehvac
Rectorseal ECM surge protector addition . . . #hvac #hvactools #hvacservice #skilledtrades #bluecollar
#Hvactools Reel by @ac_drain_wiz - If you're already performing maintenance,
add the 5-minute upgrade.
#ACDrainWiz
#hvacpro 
#hvaclife 
#hvacmaintenance 
#hvactools
206
AC
@ac_drain_wiz
If you’re already performing maintenance, add the 5-minute upgrade. #ACDrainWiz #hvacpro #hvaclife #hvacmaintenance #hvactools
#Hvactools Reel by @topgunhvacr - Meters don't always tell the full story.

Had a compressor that showed no short to ground on my meter…
but when I meg'd it out - 0 megaohms. Completel
66.9K
TO
@topgunhvacr
Meters don’t always tell the full story. Had a compressor that showed no short to ground on my meter… but when I meg’d it out — 0 megaohms. Completely grounded. If you’re only using a meter when breakers or fuses are tripping, you’re gonna miss failures like this. Always meg your motors and compressors. It’ll save you time, callbacks, and guessing. Too many techs skip this step and trust the meter… and that’s exactly how you get burned. #hvaclife #hvactech #hvac #bluecollar #skilledtrades

✨ #Hvactools発見ガイド

Instagramには#Hvactoolsの下にthousands of件の投稿があり、プラットフォームで最も活気のあるビジュアルエコシステムの1つを作り出しています。

#Hvactoolsは現在、Instagram で最も注目を集めているトレンドの1つです。このカテゴリーにはthousands of以上の投稿があり、@topgunhvacr, @adamdeckardbaby and @hvacknowitall1のようなクリエイターがバイラルコンテンツでリードしています。Pictameでこれらの人気動画を匿名で閲覧できます。

#Hvactoolsで何がトレンドですか?最も視聴されたReels動画とバイラルコンテンツが上部に掲載されています。

人気カテゴリー

📹 ビデオトレンド: 最新のReelsとバイラル動画を発見

📈 ハッシュタグ戦略: コンテンツのトレンドハッシュタグオプションを探索

🌟 注目のクリエイター: @topgunhvacr, @adamdeckardbaby, @hvacknowitall1などがコミュニティをリード

#Hvactoolsについてのよくある質問

Pictameを使用すれば、Instagramにログインせずに#Hvactoolsのすべてのリールと動画を閲覧できます。あなたの視聴活動は完全にプライベートです。ハッシュタグを検索して、トレンドコンテンツをすぐに探索開始できます。

パフォーマンス分析

12リールの分析

✅ 中程度の競争

💡 トップ投稿は平均40.0K回の再生(平均の2.7倍)

週3-5回、活動時間に定期的に投稿

コンテンツ作成のヒントと戦略

💡 トップコンテンツは10K以上再生回数を獲得 - 最初の3秒に集中

✨ 多くの認証済みクリエイターが活動中(25%) - コンテンツスタイルを研究

✍️ ストーリー性のある詳細なキャプションが効果的 - 平均長370文字

📹 #Hvactoolsには高品質な縦型動画(9:16)が最適 - 良い照明とクリアな音声を使用

#Hvactools に関連する人気検索

🎬動画愛好家向け

Hvactools ReelsHvactools動画を見る

📈戦略探求者向け

Hvactoolsトレンドハッシュタグ最高のHvactoolsハッシュタグ

🌟もっと探索

Hvactoolsを探索